xtremeDB 8 inputs 8 outputs, CANopen, Base Address 20
xDB0808-DIO CANOPEN
Mechanical Data | |
---|---|
Dimensions | 97 x 265 x 34 mm |
Weight | 680 g |
Material (Housing) | PA, reinforced |
CAN / Sensor / Module Connector | DT-4 |
Power Connector | DT-18 (A-cod.) |
IO connector | DT-4 |
Electrical Data | |
Operating Voltage | 8 … 32 V DC |
Operating Current per Contact / Potential (max.) | 13 A |
Sum Current (max.) | 26 A |
Supply Protection | Reverse polarity protection |
Block diagnoses | Undervoltage | Overvoltage | Overtemperature |
LED Indicators | Power: blue | Bus: green | Status: green | Actuator Power: blue | Signal: yellow | Error: red |
Inputs | |
Total number of inputs | 8 |
Number of digital inputs DI | 2 |
Number of analog inputs AI | 4 |
Range analog value | 4...20 mA | 0…5 V / 0…10 V / 0…32 V |
Number of frequency inputs FRQ | 2 |
Frequency Range | 10...3.000 Hz |
Input diagnoses | Undervoltage | overvoltage | short circuit |
Outputs | |
Total number of outputs | 8 |
Number of digital outputs DO | 8 |
DO output current max. | 4 A |
Number of PWM outputs | 8 |
PWM output current max. | 4 A |
Number of PWMi outputs | 8 |
PWM(i) output current max. | 4 A |
Output Protection | Overload | Short Circuit |
Output Diagnoses | Actual Current | Overcurrent | Short Circuit |
Environmental Conditions | |
Protection Class | IP67 | IP68, IP69K (with MDC cordsets) |
Ambient temperature | -40 °C…+80 °C |
Storage temperature | -40 °C…+85 °C |
Standards & Approvals | |
EMC | EN 61000-6-2 | IEC/EN 61000-6-3 | EN 61000-6-4 | ISO 13766-1 | ISO 13766-2 |
The xtremeDB -1 (pronounced: "dash one") CANopen module combines many different I/O signal configurations. It offers a total of eight inputs, up to four of which can be parameterized in analog mode. Two of the digital inputs can also be configured as frequency inputs or counters. At the same time, the module offers eight outputs, which can also be individually configured as digital, PWM or current controlled PWMi outputs. The module can drive up to 26 A output current.
Suitable For: | CCpilot V1200, xtremeDBmini, CCpilot V700, CCpilot V1000 |
Product Family: | xtremeDB |
Inputs: | 8 |
Outputs: | 8 |
Port Number: | 8 |
Interfaces: | CAN |
Connection: | DT-4, DT-18 |
Protocol: | CANopen, CAN Layer 2-B |
Baudrate: | 250, 500 kbit/s |
Input Signal Type: | DI, DI/AI, DI/FRQ/CNT |
Output Signal Type: | DO [4 A], PWM [4 A], PWMi [4 A] |
Auxiliary Voltage: | 8 … 32 V DC |
Housing Material: | Polyamide, reinforced |
Operating Temperature: | -40°C ... +80°C |
IP Rating: | IP67, IP68, IP69K |
Mounting system: | 2x 6 mm round hole + 1x slotted hole |
Standards / Approvals: | EN ISO 13766-1, ISO 13309, EN ISO 13766-2, E-Mark |
- Questions concerning this product?
- #Download EU-Konformitätserklärung | Declaration of conformity
- #Download UKCA-Konformitätserklärung | Declaration of conformity
- Datenblatt | Datasheet
- Download CAD | STEP- & DXF-Datei | STEP- & DXF File
- Download CANopen | PCAN Project
- Download CANopen | Symbol & dbc Datei | *.sym & *.dbc file
- Download Codesys | Musterprojekt | Sample Project Ecomat Display CANopen
- Download Codesys | Quickstart Guide DE
- Download Codesys | Quickstart Guide EN
- Download Configuration & Test | Quickstart Guide Block Tool EN
- Download EPLAN-Datei | EDZ-File
- Download Firmware | DPLoader Quickstart DE
- Download Firmware | DPLoader Quickstart EN
- Installationsanleitung | Installation Manual
- EPLAN Vorschau | Preview EPLAN project
- Download EPLAN-Musterprojekt | sample project
- Handbuch | User Manual CANopen DE
- Handbuch | User Manual CANopen EN
- Handbuch | User Manual J1939 / CANopen EN
- #Download E8 KBA -Zulassung | E8 KBA approval
- Download Codesys | Quickstart Guide CANopen DE
- Download Codesys | Quickstart Guide CANopen EN
- Produkt Flyer DE
- Product Flyer EN
- Download Codesys | Demoprojekt | Demo project - xtremeDB on CCPilot
- Download Configuration & Test | Block Tool for Windows
- Download Firmware | DPLoader Update Tool
- Further products by Data Panel Corp.
Suitable For: | CCpilot V1200, xtremeDBmini, CCpilot V700, CCpilot V1000 |
Product Family: | xtremeDB |
Inputs: | 8 |
Outputs: | 8 |
Port Number: | 8 |
Interfaces: | CAN |
Connection: | DT-4, DT-18 |
Protocol: | CANopen, CAN Layer 2-B |
Baudrate: | 250, 500 kbit/s |
Input Signal Type: | DI, DI/AI, DI/FRQ/CNT |
Output Signal Type: | DO [4 A], PWM [4 A], PWMi [4 A] |
Auxiliary Voltage: | 8 … 32 V DC |
Housing Material: | Polyamide, reinforced |
Operating Temperature: | -40°C ... +80°C |
IP Rating: | IP67, IP68, IP69K |
Mounting system: | 2x 6 mm round hole + 1x slotted hole |
Standards / Approvals: | EN ISO 13766-1, ISO 13309, EN ISO 13766-2, E-Mark |
- Datenblatt | Datasheet
- EPLAN Vorschau | Preview EPLAN project
- Handbuch | User Manual CANopen DE
- Handbuch | User Manual CANopen EN
- Handbuch | User Manual J1939 / CANopen EN
- Installationsanleitung | Installation Manual
- Product Flyer EN
- Produkt Flyer DE
- Further products by Data Panel Corp.
- Questions concerning this product?
- Download CAD | STEP- & DXF-Datei | STEP- & DXF File
- Download CANopen | PCAN Project
- Download CANopen | Symbol & dbc Datei | *.sym & *.dbc file
- Download Codesys | Demoprojekt | Demo project - xtremeDB on CCPilot
- Download Codesys | Musterprojekt | Sample Project Ecomat Display CANopen
- Download Codesys | Quickstart Guide CANopen DE
- Download Codesys | Quickstart Guide CANopen EN
- Download Codesys | Quickstart Guide DE
- Download Codesys | Quickstart Guide EN
- Download Configuration & Test | Block Tool for Windows
- Download Configuration & Test | Quickstart Guide Block Tool EN
- Download EPLAN-Datei | EDZ-File
- Download EPLAN-Musterprojekt | sample project
- Download Firmware | DPLoader Quickstart DE
- Download Firmware | DPLoader Quickstart EN
- Download Firmware | DPLoader Update Tool
Nachstehend die Links zu den kompatiblen Leitungen für unser xtremeDB Modul:
> Link xDB Signal-Leitungen
> Link xDB CAN-Leitungen
> Link xDB Versorgungsleitung
Below are the links to the compatible cables for our xtremeDB blocks:
> Link xDB signal cables
> Link xDB CAN cables
> Link xDB power cables