Decentralized, selective protection

The distribution and protection of potentials currently takes place mainly in the control cabinet or is hidden and difficult to access in the wiring harness. It is a challenge to selectively fuse the circuits in a small space and still keep them accessible. Data Panel's decentralized power distribution is a central component for effectively protecting the machine from cable fire.

The distribution and protection of potentials currently takes place mainly in the control cabinet or is hidden and difficult to access in the wiring harness. It is a challenge to selectively fuse... read more »
Close window
Decentralized, selective protection

The distribution and protection of potentials currently takes place mainly in the control cabinet or is hidden and difficult to access in the wiring harness. It is a challenge to selectively fuse the circuits in a small space and still keep them accessible. Data Panel's decentralized power distribution is a central component for effectively protecting the machine from cable fire.

1 From 3
No results were found for the filter!
Hint!
Power splitter 90 A, 6 potentials, ATO fuses Power splitter 90 A, 6 potentials, ATO fuses DP-38022-2-000
Mechanical Data Dimensions 169 x 134 x 53 mm Weight 600 g Material (Housing) Al, black anodized CAN / Sensor / Module Connector DT-12 Power Connector bolts Electrical Data Operating Voltage 8 … 36 V DC Operating Current per Contact /...
Content 1 Pieces
MDC06-4S power cable - open ended, 0.5m MDC06-4S power cable - open ended, 0.5m 7072-72161-P070050
Mechanical Data Weight 116 g Material (Housing) TPU Sealing Material Silicone Protection Class IP68 /IP69K Temperature Range Connector -25 °C…+85 °C Electrical Data Operating Voltage 6 … 230 V AC/DC Operating Current per Contact (max.)...
Content 1 Pieces
MDC06-4S power cable - open ended, 1.5m MDC06-4S power cable - open ended, 1.5m 7072-72161-P070150
Mechanical Data Weight 195 g Material (Housing) TPU Sealing Material Silicone Protection Class IP68 /IP69K Temperature Range Connector -25 °C…+85 °C Electrical Data Operating Voltage 6 … 230 V AC/DC Operating Current per Contact (max.)...
Content 1 Pieces
MDC06-4S power cable - open ended, 5m MDC06-4S power cable - open ended, 5m 7072-72161-P070500
Mechanical Data Weight 596 g Material (Housing) TPU Sealing Material Silicone Protection Class IP68 /IP69K Temperature Range Connector -25 °C…+85 °C Electrical Data Operating Voltage 6 … 230 V AC/DC Operating Current per Contact (max.)...
Content 1 Pieces
MDC06-4S power cable - open ended, 7.5m MDC06-4S power cable - open ended, 7.5m 7072-72161-P070750
Mechanical Data Weight 882 g Material (Housing) TPU Sealing Material Silicone Protection Class IP68 /IP69K Temperature Range Connector -25 °C…+85 °C Electrical Data Operating Voltage 6 … 230 V AC/DC Operating Current per Contact (max.)...
Content 1 Pieces
MDC06-4S power cable - open ended, 10m MDC06-4S power cable - open ended, 10m 7072-72161-P071000
Mechanical Data Weight 1168 g Material (Housing) TPU Sealing Material Silicone Protection Class IP68 /IP69K Temperature Range Connector -25 °C…+85 °C Electrical Data Operating Voltage 6 … 230 V AC/DC Operating Current per Contact (max.)...
Content 1 Pieces
MDC06-4S - MDC04-4P power connection cable , 0.25m MDC06-4S - MDC04-4P power connection cable , 0.25m 7072-77061-P070025
Mechanical Data Weight 117 g Material (Housing) TPU Sealing Material Silicone Protection Class IP68 /IP69K Temperature Range Connector -25 °C…+85 °C Electrical Data Operating Voltage 6 … 230 V AC/DC Operating Current per Contact (max.)...
Content 1 Pieces
MDC06-4S - MDC04-4P power connection cable , 0.5m MDC06-4S - MDC04-4P power connection cable , 0.5m 7072-77061-P070050
Mechanical Data Weight 146 g Material (Housing) TPU Sealing Material Silicone Protection Class IP68 /IP69K Temperature Range Connector -25 °C…+85 °C Electrical Data Operating Voltage 6 … 230 V AC/DC Operating Current per Contact (max.)...
Content 1 Pieces
MDC06-4S - MDC04-4P power connection cable , 0.75m MDC06-4S - MDC04-4P power connection cable , 0.75m 7072-77061-P070075
Mechanical Data Weight 175 g Material (Housing) TPU Sealing Material Silicone Protection Class IP68 /IP69K Temperature Range Connector -25 °C…+85 °C Electrical Data Operating Voltage 6 … 230 V AC/DC Operating Current per Contact (max.)...
Content 1 Pieces
MDC06-2S - MDC04-2P power connection cable , 1m MDC06-2S - MDC04-2P power connection cable , 1m 7072-77061-P070100
Mechanical Data Weight 204 g Material (Housing) TPU Sealing Material Silicone Protection Class IP68 /IP69K Temperature Range Connector -25 °C…+85 °C Electrical Data Operating Voltage 6 … 230 V AC/DC Operating Current per Contact (max.)...
Content 1 Pieces
MDC06-4S - MDC04-4P power connection cable , 2.5m MDC06-4S - MDC04-4P power connection cable , 2.5m 7072-77061-P070250
Mechanical Data Weight 375 g Material (Housing) TPU Sealing Material Silicone Protection Class IP68 /IP69K Temperature Range Connector -25 °C…+85 °C Electrical Data Operating Voltage 6 … 230 V AC/DC Operating Current per Contact (max.)...
Content 1 Pieces
MDC06-4S - MDC04-4P power connection cable , 5m MDC06-4S - MDC04-4P power connection cable , 5m 7072-77061-P070500
Mechanical Data Weight 629 g Material (Housing) TPU Sealing Material Silicone Protection Class IP68 /IP69K Temperature Range Connector -25 °C…+85 °C Electrical Data Operating Voltage 6 … 230 V AC/DC Operating Current per Contact (max.)...
Content 1 Pieces
1 From 3
Viewed